V3 series-centrifugal fan type

Centrifugal fan- V3T and UDSBD type which can be provided with a centrifugal pressure fan are installed in a horizontal or vertical downward air distribution system. Altogether nine specifications are available with a heating capacity ranging from 15 to 64KW.
  • Mounting allows the fan of the heater to supply air vertically (in a downward direction) to reduce heat loss caused by roof and avoid thermal stratification;
  • One temperature controller can be installed to serve as a turbulent flow fan. After the indoor temperature reaches the desired value, the fan heater will stop blowing automatically and blow the hot air near the lower part of roof to the ground to reduce energy consumption and improve environment comfort;
  • A direct-coupled centrifugal fan can provide as high as 150Pa of effective outlet air static pressure and 3 kinds of air distributors — shutter air distribution boxes are available with horizontal and vertical air distribution shutter. The downward air distribution box is provided with a shutter.
  • Model   015 020 025 030 035 043 050 055 064
    Gas Type   II 2H3+ UK
    Air inlet and exhaust ports  installation method(1)   B22, C12, C32, C42, C52, C62, C82
    Heat input(Full heat) KW 17.6 22.0 30.8 35.2 42.2 50.8 58.6 66.0 77.7
    Heat input (Net heat) KW 15.9 19.8 27.8 31.7 38.0 45.8 52.8 59.5 70.0
    Heat output KW 14.6 18.2 25.5 29.2 34.9 42.1 48.6 54.7 64.4
    Thermal efficiency % 92 92 92 92 92 92 92 92 92
    Gas consumption    
    G20 m3/h 1.68 2.10 2.94 3.36 4.02 4.85 5.59 6.30 7.41
    G25 m3/h 1.95 2.44 3.42 3.90 4.68 5.64 6.50 7.32 8.62
     G31 Kg/h 1.24 1.55 2.16 2.47 2.96 3.57 4.12 4.64 5.46
    Gas Connection   Rc 1/2
    Temp. Rise (6) oC 20 23 27 25 25 31 29 30 32
    Air volume (15oC) m3/h 2150 2350 2750 3360 4080 3900 4900 5300 5390
    Fan speeds rpm 950 950 1430 1430 950 950 950 950 950
    Flue and air inlet bore mm 80 80 80 80 100 100 100 130 130
    Recommended mounting height(Horizontal air supply)(2) m 3.5 4.0 4.5 4.5 5.5 5.5 6.0 6.0 6.0
    Air supplying distance(3) m 18 23 26 26 32 34 38 38 38
    Sound Level(4) dB(A) 50 52 47 51 46 47 52 50 53
    Sound Level(5) dB(A) 57 58 54 58 53 54 59 57 60
    Voltage  
    Note:

    (1)The category of the exhaust methods for fuel gas fumes can be treated according to the CEN report, CG1749-2001;
     (2)The installation height of the fan heater is recommended by the manufacturer and different use and installation requirements vary the planned use of the fan heater. The operation and efficiency of the fan heater are also affected by a number of external factors, such as other air treatment equipment, barriers along the intake path, cross ventilation and the doors and windows of an enclosed building. Efforts will be made to make the installation height of the fan heater exceed the recommended value, unless a downward air distributor is used. Otherwise, indoor air may become stratified, reducing the effective distribution of air and may obviously increase the thermal loss generated by roof structure;
     (3)This refers to the place where the ambient air temperature is 20 C, the air distribution shutter is 0  and the air velocity is 0.5m/s under isothermal working conditions;
     (4)dB (A) is the value at 5m distance from the fan heater in the reference environment where A=160m2 and Q=2;  (5)dB (A) refers to the open space which is 5m from the fan heater;
     (6)dB (A) is measured on the basis of 150Pa pressure of air outlet.

    Equipment size
    Model A A1 B C D E F G H J K L M N P Q R
    015,020 383 460 700 343 404 935 546 199.5 191 139 122 86 413 15.5 98 350 120
    025,030 586 590 700 546 404 1185 546 367.5 191 222 122 121 413 15.5 98 350 140
    035,043,050 510 670 970 456 601 1610 897 371 194 126 165 121 623 33 148.5 600 140
    055 663 685 970 609 601 1610 897 354 206 150 165 204 623 33 148.5 600 225
    064 663 720 970 609 601 1610 897 354 206 150 165 204 623 33 148.5 600 225

     

    the centrifugal type fuel gas fan heater can be connected to an air duct and is very suitable as an air curtain or for indoor heating.

    Query

    Product:
    Types:
    Name: Telephony:
    Company: Email:
    Message:
     

    Topower is committed to develop and disseminate an energy application system providing optimized healthy life for best energy saving and human comfort with the target of environment protection and cost control.
    Together with our value concept , "Delivers insights and explores opportunities with service-oriented" formulates our common understanding of sustainability that applies to all management areas of design, production, sales, engineering and aftermarket.
    Based on our capability and sustainable actions, we are pursuing a strategy of balancing social responsibility with profitable growth, keep reliable relationship with customer to increase the value of our company.